Installation 2 - 3
Figure 2-1
Lumped Capacitance Thermal Model of SE4750 Scan Engine
Based on this lumped capacitance thermal model and the engine power consumptions (see Table 3-7 on page
3-8), the allowed engine scanning duty cycles can be calculated and plotted for a defined engine chassis
temperature limit as Figure 2-2 and Figure 2-3.
Figure 2-2
Engine Scanning Duty Cycle in Level Trigger Mode, Chassis Temperature Limit = 60°C
Notes:
The plot represents the condition that the engine is in still air and with no heat sink attached, while the air
temperature is measured as the ambient temperature.
The scanning time is measured between the trigger event (pulling the trigger) and the end of the scanning
session (decoding).
The scanning duty cycle is the percentage of time when the engine is in full scanning mode.
0% scanning duty cycle in level trigger mode indicates that the engine is at idle.
The number of scans per minute is based on the assumption that a typical scanning session requires
1 second of full scanning power. For example, 12 scans per minute equals 20% scanning duty cycle.