EasyManua.ls Logo

Motorola SRX 2200 - Emergency Operation Continued; Emergency Operation Considerations and Exiting

Motorola SRX 2200
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Non-Tactical/Revert for Trunking System
The radio reverts to the programmed emergency talkgroup (trunking system) or channel (conventional
system) to send an alarm and/or make an emergency call.
Fall Alert (Man Down) is an alternate way to activate the Emergency feature. For more information, see Man
Down (Fall Alert) on page 56.
For more information, contact your system administrator.
7.8.1
Special Considerations for Emergency Operation
The following scenarios apply during Emergency operation:
Table 3: Emergency Operation Scenarios
Scenario Outcome
If you press the Emergency button while in a
channel that has no Emergency capability,
a tone sounds.
If you change to a channel or mode with no Emer-
gency capability while in Emergency operation,
your radio shows the following indications:
A tone sounds until you select a valid Emer-
gency channel or mode, or until you disable the
Emergency operation.
The display for Model 3.5 and Model 2.5 shows
No emergency.
The display for Model 1.5 shows NO EMERG.
If you change to a channel or mode with Emergen-
cy capability while in Emergency operation,
the Emergency Alarm and/or Emergency Call con-
tinues on the new channel or mode.
If the radio is out-of-range of the system or the
emergency alarm is not acknowledged,
your radio shows the following indications:
A tone sounds.
The display shows No acknowledge.
7.8.2
Emergency Keep-Alive
This feature prevents your radio from turning off when in Emergency mode. If this feature is enabled, you are
required to exit Emergency mode before turning off your radio.
7.8.3
Exiting Emergency Operation
If an Emergency operation is triggered on your radio, the dispatch console or radios configured as Supervisor
can exit the Emergency operation.
Procedure:
To exit Emergency operation, press and hold the programmed Emergency button.