A - 8 WT4090 Wearable Terminal User Guide
Accessories
Environmental Sealing IP54
Electrostatic Discharge
(ESD)
±15kV air discharge, ±8kV direct discharge.
Power
Cordless Standard battery: Li-Ion 970 mAh, 3.7 V with up to 35,000 scans (continuous) or up
to 10 hours with 900 scans per hour on a single charge using fresh batteries.
Extended battery: Li-Ion 1940 mAh, 3.7 V with up to 70,000 scans (continuous) or up
to 20 hours with 900 scans per hour on a single charge using fresh batteries.
Corded Corded adaptor to WT4090.
Regulatory
Electrical Safety Certified to UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, IEC 60950-1.
EMI/RFI FCC Part 15 Class B, ICES-003 Class B, European Union EMC and R&TTE
Directives, Australian AS/NZS 60950.1
Laser Safety CDRH Class II, IEC 60825-1 Class 2
RoHS Compliance with RoHS standards.
Table A-4
RS507 Technical Specifications (Continued)
Item Description
Table A-5
Accessory Specifications
Single Slot USB Cradle Four Slot Ethernet Cradle
Four Slot Spare Battery
Charger
Operating
Temperature
32 °F to 122 °F
(0 °C to +50 °C)
32 °F to 104 °F
(0 °C to +40 °C)
Storage
Temperature
-40 °F to 158 °F
(-40 °C to 70 °C)
Battery
Charging
Temperature
32 °F to 104 °F
(0 °C to +40 °C) ambient temperature
Humidity 5% to 95% non-condensing
Size (L x W x H) 6.6 in. x 5.1 in. x 3.9 in.
(16.8 cm x 13.0 cm x 9.9 cm)
6.7 in. x 18.9 in. x 4.5 in.
(17.0 cm x 48.1 cm x 11.4 cm)
8.5 in. x 5.7 in. x 1.9 in.
(21.5 cm x 14.5 cm x 4.9 cm)
Weight 12.1 oz. (344 gm) 45.9 oz. (1300 gm) 15.3 oz. (435 gm)
Power Supply 12 VDC, 3.3 A 12 VDC, 9 A 12 VDC, 3.3 A