118
Motor run
failed
Even the start signal is effective, motor
does not run
Repair required
2) Communication error (HDC driver)
code
Error
Description
How to reset
200
Parameter
reading error
Reading failure of the parameter from
the EEP-ROM of the driver
RESET button
201
Parameter
Checksum error
The read parameter is wrong by the
checksum routine
RESET button
202
Initializing error
Initializing error at the booting
Power OFF-->ON
203
Communication
error
Failure during communication with
driver
Auto reset after
set time
204
Communication
time out
Communication failure over 1 sec.
Auto reset after
set time
205
Wrong parameter
setting
Parameter on controller is wrong for
the connected screwdriver
Auto initialize