EasyManua.ls Logo

Mountz HDC-35i - Page 47

Default Icon
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3) Pattern error
code
Error
Description
How to reset
300
Fastening time limit
Over the fastening time limit on P66
Auto reset after
set time
301
Fastening time
over
Time over the set time on P21~28
Auto reset after
set time
302
Loosening time
over
Over the loosening time limit on P67
Auto reset after
set time
303
Motor lock time
over
Over the motor lock time limit on P68
Auto reset after
set time
304
Time over in screw
counting
Over the time limit of screw counting on
P77
Auto reset after
set time
305
Screw missing
When the work-piece moves out of the
working area without complete number
of fastening, it provide alarm for 3
seconds and display the latest number.
It can be clear to "0" by pressing
RESET button.
Auto reset after
set time
or RESET button
306
No torque-up
When the driver stops without torque-up
after set time in P31~38
Auto reset after
set time
307
Time laps
Torque up too earlier than the time on
P31~38
Auto reset after
set time
308
Torque NG
Monitored fastening torque(converted
torque) is out of the set tolerance
Auto reset after
set time
1080 N 11th St San Jose CA 95112
www.mountztorque.com 408.292.2214
47

Other manuals for Mountz HDC-35i