- 8 -
STEP 1: Insert the top of the DIN-
Rail into
the slot just b elo w
the stiff m etal spring.
STEP 2: The DIN-Rail
attachment unit will snap in
to
place as shown.
To remove the Moxa EtherDevice switch from the DIN-Rail, simply
reverse Steps 1 and 2.
NOTE
In order to ensure reliable operations, please make sure the
operating temp. of the environment does not exceed the spec.
When mounting a EDS
-400A switch with other operating units
in a cabinet without forced ventilation, minimum spacing of
5cm on both sid
es and above/below the switch is
recommended.
Wall Mounting (optional)
For some applications, you will find it convenient to mount the EDS-
405A/408A on the wall, as shown in the following figures.
STEP 1:
Remove the aluminum
DIN
-Rail attachment plate
from
the EDS-405A/408A’s
rear panel, and then
attach the wall mount
plates
with M3 screws, as
shown
in the diagram at
the right.
STEP 2:
Mounting
the EDS-405A/408A on the wall requires
4 screws. Use the
switch, with wall m ount plates
attached, as a guide to m ark the correct locations
of the 4 screws. The heads of the screws should be
less than 6.0 mm in diameter, and the shafts
should be less than 3.5
mm in diameter, as shown
in the figure at the right.
NOTE
Before tightening the screws into the wall, m ake sure the screw
head and shank size are suitable by inserting the screw into
one of the keyhole
-shaped ape rtures o f the wall m o unting
plates.
Do not screw the screws in completelyleave about 2 mm to allow
room for sliding the wall mount panel between the wall and the screws.