Battery type
Soltaro battery
If selected, programs of 11, 17, 18
and 19 will be automatically set up.
No need for further setting.
LIb-protocol
Select “ LIb” if using Lithium battery
compatible to Lib protocol. If
selected, programs of 11, 17, 18 and
19 will be automatically set up. No
need for further setting.
3
rd
party Lithium
battery
If selected, programs of 11, 17, 18
and 19 will be automatically set up.
No need for further setting. Please
contact the battery supplier for
installation procedure.
17
Bulk charging voltage
(C.V voltage)
Default setting: 56.4V
If self-defined is selected in program 14, this program can be
set up. Setting range is from 48.0V to 64.0V. Increment of
each click is 0.1V.
18
Floating charging voltage
Default setting: 54.0V
If self-defined is selected in program 14, this program can be
set up. Setting range is from 48.0V to 64.0V. Increment of
each click is 0.1V.
19
Low DC cut off battery voltage
setting
Default setting: 40.8V
If self-defined is selected in program 14, this program can be
set up. Setting range is from 40.8V to 48.0V. Increment of
each click is 0.1V. Low DC cut-off voltage will be fixed to
setting value no matter what percentage of load is connected.
20
Battery stop discharging
voltage when grid is available
default setting: 46V
Setting range is from 44V to 51V
and increment of each click is 1V.
5% (default)
If “WECO battery” is selected in
program 14, the parameter will be
fixed at 5% SOC of battery.