Loading...
18
12
Setting voltage point back
to utility source when
selecting “SBU” (SBU
priority) in program 01
Default setting: 46.0V
Setting range is from 44.0V to
57.0V and increment of each
click is 1.0V.
13
Setting voltage point back
to battery mode when
selecting “SBU” (SBU
priority) in program 01
The setting range is from 48.0V to 64.0V and increment of each
click is 1.0V.
Battery fully charged
54.0V (default)
16
Solar energy priority:
To configure solar energy
priority for battery and load
SbL: Solar energy for
battery first
UCB: Allow utility to charge
battery (Default)
Solar energy charges battery first
and allow the utility to charge
battery.
SbL: Solar energy for
battery first
UdC: Disallow utility to
charge battery
Solar energy charge battery first
and disallow the utility to charge
battery.
SLb: Solar energy for load
first
UCb: Allow utility to charge
battery
Solar energy provides power to the
load first and also allow the utility
to charge battery.
SLb: Solar energy for load
first
UdC: Disallow utility to
charge battery
Solar energy provides power to the
load first and disallow the utility to
charge battery.