EasyManua.ls Logo

MPP Solar PIP5048MKX - Page 19

MPP Solar PIP5048MKX
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
05
Battery type
3
rd
party Lithium battery
If selected, programs of 02, 26,
27 and 29 will be automatically
set up. No need for further
setting. Please contact the
battery supplier for installation
procedure.
06
Auto restart when overload
occurs
Restart disable (default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable (default)
Restart enable
09
Output frequency
50Hz (default)
60Hz
10
Operation Logic
Automatically (default)
If selected and utility is available,
inverter will work in line mode.
Once utility frequency is
unstable, inverter will work in
bypass mode if bypass function is
not forbidden in program 23.
Online mode
If selected, inverter will work in
line mode when utility is
available.
ECO Mode
If selected and bypass is not
forbidden in program 23,
inverter will work in ECO mode
when utility is available.
11
Maximum utility charging
current
Note: If setting value in
program 02 is smaller than
that in program in 11, the
inverter will apply charging
current from program 02
for utility charger.
30A (default)
For PIP5048MKX model, default
setting is 30A and setting range
is 1A, then from 10A to 100A.
Increment of each click is 10A.