17
03
AC input voltage range
Appliances (default)
If selected, acceptable AC input
voltage range will be within 90-
280VAC.
UPS
If selected, acceptable AC input
voltage range will be within 170-
280VAC.
05
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected,
battery charge voltage and low
DC cut-off voltage can be set up
in program 26, 27 and 29.
Pylontech battery
If selected, programs of 02, 26,
27 and 29 will be automatically
set up. No need for further
setting.
WECO battery
If selected, programs of 02, 12,
26, 27 and 29 will be auto-
configured per battery supplier
recommended. No need for
further adjustment.
Soltaro battery
If selected, programs of 02, 26,
27 and 29 will be automatically
set up. No need for further
setting.
LIb-protocol compatible
battery
Select “ LIb” if using Lithium
battery compatible to Lib
protocol. If selected, programs of
02, 26, 27 and 29 will be
automatically set up. No need for
further setting.