EasyManuals Logo

MPP Solar PIP8048MAX User Manual

MPP Solar PIP8048MAX
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
16
LCD Setting
General Setting
After pressing and holding button for 3 seconds, the unit will enter the Setup Mode. Press ” or
button to select setting programs. Press button to confirm you selection or “ button to exit.
Setting Programs:
Program
Description
Selectable option
00
Exit setting mode
Escape
01
Output source priority:
To configure load power
source priority
Utility first (default)
Utility will provide power to the
loads as first priority.
Solar and battery energy will
provide power to the loads only
when utility power is not
available.
Solar first
Solar energy provides power to the
loads as first priority.
If solar energy is not sufficient to
power all connected loads, Utility
energy will supply power to the
loads at the same time.
SBU priority
Solar energy provides power to
the loads as first priority.
If solar energy is not sufficient to
power all connected loads, battery
energy will supply power to the
loads at the same time.
Utility provides power to the loads
only when battery voltage drops
to either low-level warning
voltage or the setting point in
program 12.
02
Maximum charging current:
To configure total charging
current for solar and utility
chargers.
(Max. charging current =
utility charging current +
solar charging current)
60A (default)
Setting range is from 10A to
120A. Increment of each click is
10A.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MPP Solar PIP8048MAX and is the answer not in the manual?

MPP Solar PIP8048MAX Specifications

General IconGeneral
BrandMPP Solar
ModelPIP8048MAX
CategoryInverter
LanguageEnglish

Related product manuals