Page #21 background imageLoading...
Page #21 background image
19
13
Setting voltage point back
to battery mode when
selecting “SBU” (SBU
priority) in program 01.
Battery fully charged
54V (default)
Setting range is from 48V to 58V. Increment of each click is 1V.
16
Charger source priority:
To configure charger
source priority
If this inverter/charger is working in Line, Standby or Fault
mode, charger source can be programmed as below:
Solar first
Solar energy will charge battery
as first priority.
Utility will charge battery only
when solar energy is not
available.
Solar and Utility (default)
Solar energy and utility will
charge battery at the same time.
Only Solar
Solar energy will be the only
charger source no matter utility is
available or not.
If this inverter/charger is working in Battery mode, only solar
energy can charge battery. Solar energy will charge battery if it's
available and sufficient.
18
Alarm control
Alarm on (default)
Alarm off
19
Auto return to default
display screen
Return to default display
screen (default)
If selected, no matter how users
switch display screen, it will
automatically return to default
display screen (Input voltage
/output voltage) after no button
is pressed for 1 minute.