Installation 6-5PTX-PRO User and Technical Manual
Figure 6-5: Complete Tripod Installation - Typical
6.6 Power Connections
6.6.1 Power Requirements
The PTX-PRO has the following power requirements, depending
upon the power option utilized.
Supply Voltage: +11.0 to +36 Volts DC
90 to 264 VAC, 50/60 Hz
Quick Release
Mount
PTX-PRO (Typical)
Antenna Lock
Plate
Antenna
(2 Options
Shown)
Tripod
Power Consumption: 50 watts nominal
6.6.2 Power Supply and Distribution
AC or DC power is supplied externally, from an external power
source.
CAUTION
Avoid possible equipment damage. If you
are using a DC power source for your PTX-
PRO, do not exceed 36 volts DC input
power.
Power is distributed to the PTX-PRO through the front panel
PWR connector on the PTX-PRO.
CAUTION
To avoid possible equipment damage, turn
off DC Power on the coax before connecting
any test equipment.
Panel Power Connections The PTX-PRO power connector is
located on the front panel. The mating connector that plugs into
this panel connector is described below.
Manufacturer: ITT Cannon
Part Number KPTR06F14-12SX
Description: 12-Pin, Female, Plug
Manufacturer: Amphenol
Part Number PT06E14-12SX
Description: 12-Pin, Female, Plug