MSA TECHNICAL DATA
S-Cap-Air 17
9. Technical Data
Weight
§
With 3L 200 bar steel cylinder: approx. 6 kg
§
With 3L 300 bar COMPOSITE-cylinder: approx.
< 5 kg
Method of carrying
§
On the chest with neck harness
Storage temperature
-
15°C to +50°C
Service life
§
Hood and tubing:
if stored according to ISO 2230: 10 years
§
Steel cylinder:
Check intervals in accordance with national
regulations
§
COMPOSITE-cylinder: 15 years (see Label)
Check intervals in accordance with national
regulations.
Breathing air
§
In accordance with EN 12021 or USCGA grade D
Temperature of the
inhalation air
§
Corresponding to the storage temperature
Air supply time
15 minutes