Press the MODE or +/- key to select one of the available choices for each print field.
PRODUCT
INTERFACE
TEMPERATURE
GOVP
GOVI
NSVP
MASS
GOVT
GOVU
BLANK
Printer reports can be scheduled in two ways. The user can select PRINT EVERY HOUR
or print by customized PROGRAMMED TIMES. Press the MODE key to select the desired
print scheduler mode.
If PROGRAMMED TIMES is selected, the user can input up to 12 different print times.
Press the MODE key to change the selected PRINT INTERVAL or ENTER to continue to
the next PRINT INTERVAL.
Print times must be entered in 24 hour clock format. Enter hours first, followed by min-
utes. Enter 99:99 to disable the selected print interval.
PRINT INTERVAL #1
--:--
(HOURS:MINUTES)
‘Enter’ NEW VALUE
PRINT INTERVAL #1
14:30
‘Mode’ TO CHANGE
‘Enter’ TO CONTINUE
NOTE
Print reports can also be scheduled by pressing the
"0" key during measurement mode.
PRINT INTERVAL
ONCE EVERY HOUR
‘Mode’ TO CHANGE
‘Enter’ TO CONTINUE