Temposonics
®
R-Series V Analog
Operation Manual
4.6 Electrical connections
Placement of installation and cabling have decisive influence on
the sensor‘s electromagnetic compatibility (EMC). Hence correct
installation of this active electronic system and the EMC of the entire
system must be ensured by using suitable metal connectors, shielded
cables and grounding. Overvoltages or faulty connections can damage
its electronics despite protection against wrong polarity.
Instructions for connection
Use low-resistant twisted pair and shielded cables. Connect
the shield to ground externally via the controller equipment.
Keep control and signal cables separate from power cables and
sufficiently far away from motor cables, frequency inverters,
valve lines, relays, etc..
Use only connectors with metal housing and connect the shielding
to the connector housing.
Keep the connection surface at both shielding ends as large
as possible. Connect the cable clamps to function as a ground.
Keep all non-shielded leads as short as possible.
Keep the earth connection as short as possible with a large
cross section. Avoid ground loops.
With potential differences between machine and electronics earth
connections, no compensating currents are allowed to flow across
the cable shielding.
Recommendation:
Install potential compensating leads with large cross section,
or use cables with separate double shielding, and connect only
one end of the shield.
Use only stabilized power supplies in compliance with the
specified connecting ratings.
Grounding of profile and rod sensors
Connect the sensor electronics housing to machine ground. Ground
sensor types RP5 and RH5 via ground lug as shown in Fig. 22. In
addition you can ground the sensor type RH5 via thread.
Connector wiring
Connect the sensor directly to the control system, indicator or other
evaluating systems as shown.
Fig. 22: Grounding via ground lug (e.g. RH5)
Fig. 23: Location of connection
Fig. 24: Connector wiring D60
NOTICE
1. Do not mount the sensors in the area of strong magnetic or
electric noise fields.
2. Never connect / disconnect the sensor when voltage is applied.
NOTICE
1. In addition to the functions listed for the output 2 wiring
connections, pins 3 and 4 (or the yellow and green wires) can
also be used with the hand or cabinet programmers for analog
output to perform field programming of the setpoint 1 and 2
positions (refer to section 5.4).
2. If output 2 is not used, these connections should still remain
available for possible field programming with the hand or
cabinet programmers for analog output. However, to avoid
accidentally engaging the programming mode on sensor power
up, these connections must be insulated to prevent shorting
with each other or being grounded.
M16 connector
D60
Signal + power supply
M16 male connector Output Pin Function
1
2
3
6
5
4
View on sensor
1
1 Position (magnet 1)
2 Signal Ground
2*
3
Position (magnet 2) or
reverse position (magnet 1) or
speed or velocity (magnet 1) or
temperature inside the sensor
electronics housing
4 Signal Ground
5 +12…30 VDC (±20 %)
6 DC Ground (0 V)
* order dependent
Fig. 25: Wiring for cable outlet
HXX / RXX / TXX
Signal + power supply
Cable Output Color Function
1
GY Position (magnet 1)
PK Signal Ground
2*
YE
Position (magnet 2) or
reverse position (magnet 1) or
speed or velocity (magnet 1) or
temperature inside the sensor
electronics housing
GN Signal Ground
BN +12…30 VDC (±20 %)
WH DC Ground (0 V)
* order dependent
For cable type TXX, the extra red and blue wires are not used.

Questions and Answers: