Temposonics
®
R-Series V Analog
Operation Manual
I 5 I
3.1 Order code of Temposonics
®
RP5
3. Identification
a Sensor model
R P
5
Pro le
b Design
G
Magnet slider backlash free (part no. 253 421)
L
Block magnet L (part no. 403 448)
M
U-magnet OD33 (part no. 251 416-2)
N
Magnet slider longer ball-jointed arm (part no. 252 183)
O
No position magnet
S
Magnet slider joint at top (part no. 252
182)
V
Magnet slider joint at front (part no. 252
184)
c Mechanical options
A
Standard
V
Fluorelastomer seals for the sensor electronics housing
.
d Stroke length
X X X X M
0025…6350 mm
Standard stroke length (mm) Ordering steps
25 500 mm 25 mm
5002500 mm 50 mm
25005000 mm 100 mm
5000
6350 mm 250 mm
X X X X
U
001.0…250.0 in.
Standard stroke length (in.) Ordering steps
1 20 in. 1.0 in.
20100 in. 2.0 in.
100200 in. 4.0 in.
200250 in. 10.0 in.
Non-standard stroke lengths are available;
must be encoded in 5 mm/0.1 in. increments.
.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
R P 5 0
1
a b c d e f g h i j k l
optional
e Number of magnets
0 X
01…02 Position(s) (1…2 magnet(s))
f Connection type
D
6 0 M16 male connector (6 pin)
H
X X
XX m PUR cable (part no. 530 052)
H01…H30 (1…30 m/3…99 ft.)
See “Frequently ordered accessories” for cable
speci cations
R X X
XX m PVC cable (part no. 530 032)
R01…R30 (1…30 m/3…99 ft.)
See “Frequently ordered accessories” for cable
speci cations
T X X
XX m Tefl on
®
cable (part no. 530 112)
T01…T30 (1…30 m/3…99 ft.)
See “Frequently ordered accessories” for cable
speci cations
*/ Encode in meters if using metric stroke length.
Encode in feet if using US customary stroke length
g System
1
Standard
h Output
A
Current
V
Voltage
i Function
1
Position (1 or 2 magnets/outputs)
2
Position and speed (1 magnet and 2 outputs)
3
Position and velocity (1 magnet and 2 outputs)
4
Position and reverse position (1 magnet and 2 outputs)
5
Position and temperature inside the sensor electronics housing
(1 magnet and 2 outputs)
6
Differential (2 magnets and 1 output)
j Options
0
Standard
k Output range
0
0…10 VDC or 4…20 mA
1
10…0 VDC or 20…4 mA
2
−10…+10 VDC or 0…20 mA
3
+10…−10 VDC or 20…0 mA