Temposonics
®
R-Series V Analog
Operation Manual
I 6 I
l Max speed or velocity value
(optional: use when
“Function” is 2 or 3)
For metric stroke lengths encode speed or velocity in
m/s for the values 0.01 to 9.99 m/s (001…999)
For US customary stroke lengths encode speed or velo-
city in inches/s for the values 1 to 400 in./s (001…400)
Use the codes (00E) for 0.025 m/s, and (A00) for 10.0 m/s to provide backwards
compatibility for these predecessor model of the R-Series.
NOTICE
• For RP5, the magnet selected in
b
“Design” is included in
the scope of delivery. Specify the number of magnets for your
application. For multi-position measurements with more than
1magnet order the other magnets separately.
• The number of magnets is limited by the stroke length.
The minimum allowed distance between magnets (i.e. front face
of one to the front face of the next one) is 75 mm (3 in.).
• Use magnets of the same type for multi-position measurement,
e.g. 2 × U-magnet (part no. 251 416-2).