Number of cylinders 16
Number of inlet valves, per cylinder 2
Number of exhaust valves, per cylinder 2
LUBE OIL SYSTEM
Number of cylinders 16
Lube oil operating temperature before engine, from R °C 86
Lube oil operating temperature before engine, to R °C 91
Lube oil operating pressure before engine, from R bar 6.4
Lube oil operating pressure before engine, to R bar 7.4
Lube oil operating pressure, low idle (meas. point: before engine) R bar 3.0
FUEL SYSTEM
Number of cylinders 16
Fuel pressure at supply connection to engine (when engine is starting), min. L bar -0.3
Fuel pressure at supply connection to engine (when engine is running),
min.
L bar -0.3
Fuel pressure at supply connection to engine (when engine is starting),
max.
L bar +0.5
Fuel supply flow, max. R liter/min 29
GENERAL OPERATING DATA
Number of cylinders 16
Firing speed, from R rpm 100
Firing speed, to R rpm 120
STARTING (electric)
Number of cylinders 16
Rated starter voltage (standard design) R V= 24
INCLINATIONS – STANDARD OIL SYSTEM (ref.: water line)
Number of cylinders 16
Longitudinal inclination, continuous max., driving end down (Option: max.
operating inclinations)
L degree 15
Longitudinal inclination, temporary max., driving end down (Option: max.
operating inclinations)
L degree 22.5
Longitudinal inclination, continuous max., driving end up (Option: max. op‐
erating inclinations)
L degree 0
Longitudinal inclination, temporary max., driving end up (Option: max. oper‐
ating inclinations)
L degree 6
Transverse inclination, continuous max. (Option: max. operating inclina‐
tions)
L degree 22.5
Transverse inclination, temporary max. (Option: max. operating inclinations) L degree 35
46 | Technical Data | MW15407/14E 2012-02
TIM-ID: 0000003025 - 002