4.13 Emergency stop from LOP (without Blue Line automation
system)
CAUTION
An emergency stop causes extreme stress to the engine.
Risk of overheating, damage to components!
• Initiate emergency stop only in emergency situations.
Emergency stop from LOP
Item Task
LOP Open cap of EMERGENCY STOP button (→ Page 50).
LOP Press EMERGENCY STOP button.
• Engine is stopped by switching power supply to ECU off;
• Engines with emergency air-shut-off flaps: Flaps close;
• EMERGENCY STOP button flashes, signalization by horn, flash lamp
etc. is released.
After emergency stop from LOP
Item Task
LOP Press ALARM ACKNOWLEDGE button (→ Page 50).
• Audible and visual signalization stops.
LOP Press ALARM ACKNOWLEDGE button again.
• Power supply to ECU is provided;
• Alarm is acknowledged.
Engine Engines with emergency air-shut-off flaps: Open flaps.
• Engine is ready for operation.
MW15407/14E 2012-02 | Operation | 63
TIM-ID: 0000002313 - 002