4.13 Emergency stop from LOP (without Blue Line automation
system)
CAUTION
An emergency stop causes extreme stress to the engine.
Risk of overheating, damage to components!
Initiate emergency stop only in emergency situations.
Emergency stop from LOP
Item Task
LOP Open cap of EMERGENCY STOP button (→ Page 50).
LOP Press EMERGENCY STOP button.
Engine is stopped by switching power supply to ECU off;
Engines with emergency air-shut-off flaps: Flaps close;
EMERGENCY STOP button flashes, signalization by horn, flash lamp
etc. is released.
After emergency stop from LOP
Item Task
LOP Press ALARM ACKNOWLEDGE button (→ Page 50).
Audible and visual signalization stops.
LOP Press ALARM ACKNOWLEDGE button again.
Power supply to ECU is provided;
Alarm is acknowledged.
Engine Engines with emergency air-shut-off flaps: Open flaps.
Engine is ready for operation.
MW15407/14E 2012-02 | Operation | 63