3. Basic settings
The ROXXY Smart Control MSB is supplied already
set up to suit the majority of powered gliders and
power models. These are the default settings:
Basic settings, control functions:
Battery type LiPo
Cut-off voltage LiPo - automatic
Cut-off response Reduce power
S-BEC voltage [V] 6.0V
Soft-start On
Soft-start speed Normal
Brake On
Brake response Hard
Braking effect 100%
Motor direction Forward
Motor pole count 14 (outrunner)
Motor timing 15°
Torque Normal
Governor mode Off
Governor stabilize Off
If you require a conguration which varies from
these settings, you will need to recongure the
speed controller.
In this case please continue as described in the
Chapter entitled “Conguration”.
Basic settings, telemetry functions:
Battery voltage display Address 2
Battery voltage alarm Off
Battery charge display Address 3
Battery charge alarm Off
Charge display auto-reset > 4.10V
Current display Address 4
Excess current warning Fixed type-dependent
Temperature display Address 5
Temperature warning Fixed at 100°C
RPM display Address 6
Gearbox reduction ratio 1:1
Servo travels (xed-wing)
Full-throttle 2050µs
Mid-point 1500µs
Throttle off / (brake) 1050µs
Servo travels (car / boat)
Forward 2050µs
Throttle / idle (brake) 1500µs
Reverse 1050µs