EasyManua.ls Logo

Multitech MultiModem II MT5600BA–V.90 - Callback Operation and Commands

Multitech MultiModem II MT5600BA–V.90
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 - Callback Security
38
Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide
8. Press à, à to go to the ENTER NUMBER #2? screen.
9. Repeat steps 3–7 to enter the next number.
10. Repeat as many times as necessary, up to memory location 30, until all numbers
have been entered.
Warning: There is no way to review an entry to confirm that it has been entered cor-
rectly. If you attempt to look at a number entry by pressing the Enter button for an
ENTER NUMBER #n? screen, it is possible for you to accidentally erase the entry.
Calling Procedure
Use the following procedure to call a modem that has callback security enabled.
Note: Autoanswer must be enabled on the calling modem (S0=1 or S0=2).
1. Using a data communication program such as HyperTerminal, dial the number of
the callback modem.
2. When the connection is established, the callback modem responds with a re-
quest for a password.
3. Type the password for your modem, and then press ENTER. You have three at-
tempts to enter a valid password or be disconnected.
4. If the password is valid, the callback modem disconnects. Then, after a short
delay, it calls the number associated with the password and establishes a work-
ing connection.
Note: If you are calling a direct connect number, you must append a hyphen (-) to
the password. If the corresponding phone number has
-
as its first character, you will
be able to go directly online with the callback modem. If the corresponding phone
number has no
-
character, you will be prompted for a different password.