EasyManua.ls Logo

Muncie ADVANTAGE + - Page 11

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
EXPLANATION OF SPREADER CIRCUIT
HYDRAULIC
Proportional Valve (SP3) – Spinner ow control valve. SP3 is a proportional solenoid ow control valve.
In its un-energized state it provides a blocked path between the pump ow and the spinner work port. When it is
energized it provides an increasing orice opening to ow as a result of increasing electric current to its solenoid coil.
Proportional Valve (SP2)Auger/Conveyor ow control valve. SP2 is a proportional solenoid ow control valve. In its
non-energized state it provides a blocked path between the pump ow and the auger/conveyor work port. When it is
energized it provides an increasing orice opening to ow as a result of increasing electric current to its solenoid coil.
Relief Valve (RV3)Spreader Pressure Relief. RV3 limits the pressure of the spreader motor circuits. It is located in
the pilot load-sense line of the spreader work ports. It ultimately limits the pressure at the RV1 and therefore EV1 which
opens to dump pump ow to tank. RV3 is adjustable. Its pressure setting will be displayed at the LSGP if a spreader
motor load exceeds the relief setting or a blockage of a spreader work port occurs.
CV8 & CV9 CV8 and CV9 are back-to-back check valves. Their purpose is to communicate the higher of the two
spreader motor pressures of the hoist circuit back to the RV1 boost pressure relief.
CP1 – Auger Reverse Cavity – This cavity can be populated with a solenoid actuated, 2 position / 2 way cartridge to
reverse the auger ow.