© Munters AB, 2018 11
3.2 Feeding Time
There are ten table entries for times at which to schedule daily feedings. The time programmed is the
beginning and end of each meal for mealtime feeding. For multiple feedings, the RFS-6 Broiler feeds
equal portions of the day’s ration at each feeding. For full feeding, set the quantity/bird on the Feeding
Curve Table to a high number (default - 1Kg/Bird). The feeding time table operates relays 5 and 6 (as
extra feeder) which calls starts at the times specified in the table.
3.3 Feed Mixing
The RFS-6 Broiler supports blending of three feed sources. Enter the percentage for either Auger 2 or
Auger 3 at each programmed growth day. The RFS-6 Broiler automatically adjusts Auger 1 to total
100%. System parameter 1 controls the number of mixing cycles required prior to feed delivery.
NOTE System parameter 1 controls the number of mixing cycles required prior to feed delivery.
3.4 Lighting
The Lighting option controls the flock's light periods. Enter up to ten time periods for the lights to turn on.
3.5 Operation Mode
The operation mode controls the filling process. There are three modes:
• AUTO: The load cell continually weighs the weighing container and allows filling as needed.
• BYPASS: Container is filled by time (for example 5 kilograms per minute). Use this option only
if the load cell is not working. Feed Scaling automatically calibrates itself at 0:00 AM, so there
is no need to calibrate the quantity.
• STOP: Stops the filling process.