7 Calibration menu
The following sections detail the calibration processes.
Feed Scale
Bird Scale
Feed Factor
Bird Scal
Modem Setting
7.1 Feed Scale
The feed scale periodically requires calibration.
To calibrate the feed scale:
1. When the scale is empty, press Enter.
2. Place a known weight on the scale and enter its value.
3. Press Enter and a success/failure message appears.
7.2 Bird Scale
To calibrate the poultry scale, you need an accurate weight (minimum one pound / 454 grams;
maximum 50 pounds / 20 kilograms). To obtain an inexpensive known weight, use a two liter soda
bottle (or equivalent). Weigh it on an accurate calibrated scale such as those used in grocery stores.
Follow the instructions on the display.
NOTE To calibrate accurately, Munters recommends using five kilograms or more of a known weight.
7.3 Feed Factor
Munters factory calibrates each feed scale platform prior to shipment. Instead of using an accurate
weight, you may simply enter the calibration number from the scale. There is also a zero (tare) number
for the feed scale that needs to be entered. The feed factor and the zero number are set automatically
after a good calibration.
KEEP POULTRY SCALE
EMPTY, PRESS ENTER
KEEP FEED CONTAINER
EMPTY, PRESS ENTER