© Munters AB, 2018 30
9 RFS-6 Broiler Quick Guide
This section provides a basic setup guide for the RFS-6 Broiler. For a more detailed guide, refer to the
previous sections.
•
Installation
•
Calibration Menu
•
Control Menu
9.1 Installation
1. Connect the Main Silo Auger to Relay 1.
2. Connect the RFC valve to Relay 3.
3. Connect the feeder to Relay 5.
9.2 Calibration Menu
•
In Calibration > Feed Scale, calibrate the RFC-1. Refer to the manual for detailed instructions.
9.3 Control Menu
1. In Control > Feeding Curve, define the daily amount of feed to be delivered, per bird.
NOTE This process begins at midnight. To set a different time, go to Control > System Parameters >
Midnight. Set the required time to weigh the feed.
2. In Control > Feed Time, define the time period that the feeders operate (receive feed from the
hoppers) and cycle time.
3. In Control > Operation Mode, define how the feeders operate:
•
Automatically: according to RFS-6's configuration
•
Bypass: according to a fix amount (weight/time)
•
Stop: feeders cease to operate
NOTE Refer to the RFS-6 manual for details.