Example: Record a Macro to the [0] key to Turn on the M32.
1 Select “Input 1” (Source 1), and commence playback of connected
Source 1 device (as in BD player).
2 On the HTRM 2, simultaneously press-and-hold [MACRO] and [0]
(numeric zero); the Learn LED turns steady green.
3 Press [AMP]; press [ON]; press [1] (“Input or Source 1”); press [BD]; press
[4] (Play) - the Learn LED blinks as each step is added.
4 Press [MACRO] again to exit the macro-record mode.
To clear a macro, perform the above steps without entering any functions.
NOTE
Each macro can store a maximum of 64 command steps. If you exceed
this number, the macro will be stored automatically after the 64th
command is added.
EXECUTING MACROS
1 Press and release [MACRO]; its key lights for 5 seconds. While it remains
lit, press an HTRM 2 key where a macro has been stored.
2 The corresponding macro will run; as each step executes, its “parent”
Device Selectors key ashes briey.
3 When nished, the [MACRO] key illumination goes out.
Pressing any other HTRM 2 key while a macro is executing will abort the
macro. Remember that you must hold the HTRM 2 so that its infrared
emitter can activate the target components.
NOTE
When a macro executes, a 1 second delay is automatically inserted
between its commands. If you need more than a 1 second delay between
particular commands—for example, to permit a component to power
up completely—you can record “empty” steps into the macro by
changing Device Selector “pages” without entering actual command
functions.
KEY ILLUMINATION TIMEOUT
The HTRM 2’s key-illumination can be set to remain lit for 0-9 seconds. The
default value is 2 seconds.
SET THE ILLUMINATION TIMEOUT
1 Simultaneously press and hold the HTRM 2’s [DISP] and the [0-9] key
corresponding to the desired timeout duration.
2 The Learn LED will ash twice to conrm the new setting.
3 When set to zero, the illumination will not turn on at all.
NOTES
Key illumination is activated when one presses any HTRM 2 key.
If HTRM 2 senses movement, key illumination is activated without
having to press a key. If HTRM 2 is shaken, key illumination is also
activated.
Key illumination is the biggest drain on the HTRM 2’s batteries. A short
key illumination timeout will extend battery life appreciably; turning it
o altogether (set it to 0 seconds) will lengthen it still further.
CONFIGURING KEY ILLUMINATION
Keys to Press (for 3 seconds) Mode
DISP + Digit Key (0-9) Set key illumination timeout to number of
seconds corresponding to digit key. Zero turns o
the key illumination entirely.
DISP + OFF Disable light sensor. Key illumination will turn on
with any key press.
DISP + ON Enable light sensor.
DISP + ENTER Set the light sensor threshold to the current
light level.
DISP + RTN Restore all key illumination settings to the
defaults.
FACTORY RESET
The HTRM 2 can be reset to its factory state, deleting all learned commands,
copied and punched-through keys, macros, and other setup information,
reverting all keys to their pre-programmed library commands.
PERFORM A FACTORY RESET
1 Simultaneously press-and-hold the HTRM 2’s [ON] and [RTN] keys for 10
seconds. The Learn LED will start to ash green.
2 Release [ON] and [RTN] before the second ash is complete; the Learn
LED will turn red, indicating the remote has been reset.
NOTE
Release [ON] and [RTN] before the second ash goes out; otherwise, the
unit will not reset. Should this occur, repeat the full procedure.
DELETE MODE
The HTRM 2 can store learned, copied, and default library commands on
any single key. The default library commands are the pre-programmed NAD
codes, such as the native M32 commands on the [AMP] page.
You can delete commands by layers back down” to the default library
command on any key, removing learned commands, punched-through
functions, and copied keys.
NOTE
The default library commands cannot be deleted.
ENTER DELETE MODE
1 Simultaneously press-and-hold the desired keys Device Selector key
and the [RTN] key for 3 seconds, until the Learn LED turns green.
2 Press the function key whose command you wish to delete; the Learn
LED ashes; the number of times indicates which type of function has
become active - see the table below.
3 Press the active Device Selector key again to exit Delete Mode.
NOTE
You can delete multiple function-key commands on the same Device
Selector “page”. To delete more than one Device Selector page, exit
Delete mode and then re-enter the required page.
Flashes Command Type
1 Default Library Command
2 Copied Library Command
3 Learned Command
OPERATION
USING THE HTRM 2 REMOTE CONTROL
19
ENGLISHFRANÇAISESPAÑOLITALIANODEUTSCHNEDERLANDSSVENSKAРУССКИЙ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAD M32 and is the answer not in the manual?

NAD M32 Specifications

General IconGeneral
Damping factor800
Amplifier class-
Frequency range20 - 96000 Hz
Output impedance240 Ω
Audio output channels- channels
Peak power per channel195 W
Signal-to-Noise Ratio (SNR)92 dB
Total Harmonic Distortion (THD)0.005 %
Dynamic power per channel (2 Ohm)400 W
Dynamic power per channel (4 Ohm)360 W
Dynamic power per channel (8 Ohm)220 W
Power consumption (standby)0.5 W
Power consumption (typical)40 W
LED indicatorsYes
Package weight18500 g
Product colorBlack, Grey
Connectivity technologyWired
Weight and Dimensions IconWeight and Dimensions
Depth396 mm
Width435 mm
Height133 mm
Weight9800 g