troubleshooting
9.0 troubleshooting
symptom problem test solution
Flame is a blue,
Blockage in vent. - Remove blockage. In really cold conditions, ice buildup may
occur on the terminal and should be removed as required.
White / grey film forms
on glass.
Sulphur from fuel is being
depos
-
ited on glass, logs, or
-
surfaces.
- Clean the glass with a recommended gas fireplace glass
cleaner.
DO
NOT CLEAN GLASS WHEN HOT.
-
If sulphur deposits are not cleaned off regularly, the glass may
become permanently marked.
Exhaust fumes smelled
in room, headaches.
Appliance may be leaking
exhaust fumes into the room.
- Check firebox glass door was properly reinstalled after cleaning
If not rectified, turn off appliance. Contact a qualified technician.
Pilot will not light. Makes
noise with no spark at
pilot burner.
No siginal from remote with no
pilot ignition.
- Reprogram receiver code.
- Replace battery holder (including switch), if applicable.
Pilot sparks but will
not light.
Gas supply. - Contact a qualified technician.
Out of propane gas. - Fill the tank.
Remote control (if equipped). - Follow reprogramming instructions for specific remote
installed with your appliance.
- Replace remote control.
Battery holder (including
switch) is in “off
position; burner comes
on.
Battery holder (including wall
switch) mounted upside down.
- Reverse.
Battery holder (including switch)
and/or wire is grounding.
- Replace.
- Check for ground (short); repair ground or replace wire.
Faulty wire - Replace.
Remote control and/or
battery holder (including
switch) is not functioning
properly.
Remote control lights but
no spark or flame. (Remote is
locked out).
- Reset by turning power source off then on.
Battery holder (including switch)
or remote has low battery.
- Replace batteries.
Error with synchronizing. - Reset battery holder (including switch) and remote control.
Remote too far away from
battery holder (including switch).
-
Refer to “wiring diagram” section in the Installation manual.
note:
Flames are very
aggressive.
Door is open. - Ensure door is secured properly. If not rectified, contact a
qualified technician.
Appliance won’t
perform any
functions.
No power to the system.
- Check breaker to verify it’s in the “on” position.
Battery holder (including switch)
in wrong position (if equipped).
- Verify that the 3 position switch on the battery holder (including
switch) is in the remote position (middle).
Battery holder, battery holder
(including switch) and/or remote
control isn’t operational.
-
Check battery power and battery orientation.
lazy, transparent flame

Table of Contents

Other manuals for Napoleon Ascent Deep Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Napoleon Ascent Deep Series and is the answer not in the manual?

Napoleon Ascent Deep Series Specifications

General IconGeneral
BrandNapoleon
ModelAscent Deep Series
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals