7
W415-0773 / E / 03.13.12
2.4 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
GD36 RATES AND EFFICIENCIES BGD36 RATES AND EFFICIENCIES
NG LP NG LP
Altitude (FT) 0-4,500 0-4500 Altitude (FT) 0-4,500 0-4,500
Max. Input (BTU/
HR)
26,000 26,000 Max. Input
(BTU/HR)
18,000 17,000
Max. Output
(BTU/HR)
22,360 22,880 Max. Output
(BTU/HR)
11,500 10,900
Effi ciency
(w/the fan on)
86% 88% Effi ciency
(w/the fan on)
64% 64%
A.F.U.E. 64% 65% A.F.U.E. 53% 53%
Min. Inlet Gas
Supply Pressure
4.5" Water
Column
11" Water
Column
Min. Inlet
Gas Supply
Pressure
4.5" Water
Column
11" Water
Column
Max. Inlet Gas
Supply Pressure
7" Water
Column
13" Water
Column
Max. Inlet
Gas Supply
Pressure
7" Water
Column
13" Water
Column
Manifold
Pressure (Under
Flow Conditions)
3.5" Water
Column
10" Water
Column
Manifold
Pressure
(Under Flow
Conditions)
3.5" Water
Column
10" Water
Column
This appliance is approved for bathroom, bedroom and bed-sitting
room installations and is suitable for mobile home installation.
No external electricity (110 volts or 24 volts) is required for the gas
system operation.
Expansion / contraction noises during heating up and cooling
down cycles are normal and are to be expected.
66.4%
GD36