2.4 GENERAL INFORMATION
4.12A
This product must be installed by a licensed plumber or gas tter when installed within the commonwealth
of Massachusetts.
The appliance damper must be removed or welded in the open position prior to installation of a appliance
insert or gas log.
The appliance off valve must be a “T” handle gas cock.
• The exible connector must not be longer than 36 inches (914mm).
A Carbon Monoxide detector is required in all rooms containing gas red appliances.
The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent
sealed combustion product.
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
A
NSI Z223.1 and NFPA 54 in the United States.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certied in the U.S.
by the National Fireplace
Institute
®
(NFI) as NFI Gas
Specialists
www.ncertied.org
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
GDI-30
NG LP
Altitude (FT) 0-4,500 0-4,500
Max. Input (BTU/HR) 24,500 24,500
Max. Output (BTU/HR) 20,825 20,825
Ef ciency (w/the fan on) 85% 85%
A.F.U.E. (maximum value) 82% 82%
Min. Inlet Gas Supply Pressure 4.5" (11mb) Water Column 11" (27mb) Water Column
Max. Inlet Gas Supply Pressure 7" (17mb) Water Column 13" (32mb) Water Column
Manifold Pressure (Under Flow Conditions) 3.5" (9mb) Water Column 10" (25mb) Water Column
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of speci c
recommendations from the local authority having jurisdiction, the certi ed high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating up
and cooling down cycles are normal and to be expected.
This appliance is not approved for closet or recessed installations. It
is approved for bathroom, bedroom and bed-sitting room installations
and is suitable for mobile homes. The natural gas model is suitable for
installation in a mobile home that is permanently positioned on its site
and fuelled with natural gas.
A barrier designed to reduce the risk of burns from the hot viewing
glass is provided with the appliance and shall be installed.
64.5%
GDI-30

Table of Contents

Other manuals for Napoleon GDI-30N

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Napoleon GDI-30N and is the answer not in the manual?

Napoleon GDI-30N Specifications

General IconGeneral
BrandNapoleon
ModelGDI-30N
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals