3.3 GAS INSTALLATION
3.4 OPTIONAL WALL SWITCH
30.1A
Installation and servicing to be done by a quali ed installer. Do not use open ame.
Move the appliance into position and secure.
If equipped with a ex connector the appliance is designed to accept a 1/2” (13mm) gas supply.
Without the connector it is designed to accept a 3/8” (9.5mm) gas supply. The appliance is equipped
with a manual shut off valve to turn off the gas supply to the appliance.
Connect the gas supply in accordance to local codes. In the absence of local codes, install to the
current CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI
Z223.1 / NFPA 54 in the United States.
• When exing any gas line, support the gas valve so that the lines are not bent or kinked.
Check for gas leaks by brushing on a soap and water solution.
!
WARNING
RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS
SPARKS OR OPEN FLAMES.
SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT
WITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BE
PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT
THE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS AND
ELECTRICAL LOCATIONS, SEE “DIMENSION” SECTION.
ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GAS
LINE AT TEST PRESSURES ABOVE 1/2 PSIG.
VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.
For ease of accessibility, an optional remote wall switch may be installed in a convenient location. Route a
2 strand, solid core millivolt wire from the valve to the wall switch. The recommended maximum lead length
depends on wire size:
WIRE SIZE MAX. LENGTH
14 gauge 100 feet (30.5m)
16 gauge 60 feet (18.3m)
18 gauge 40 feet (12m)
Disconnect the existing wires from terminals 1 and 3 (from the
ON/OFF switch) and replace with the leads from the wall switch.
50.5
P
I
L
O
T
TP
!
WARNING
DO NOT CONNECT THE WALL SWITCH OR GAS VALVE DIRECTLY TO 110 VOLT ELECTRICITY.
1
3
P
I
P
I
L
O
T
N
O
L
O
T
H
I
L
O
F
F
O
A
B

Table of Contents

Other manuals for Napoleon GDI-30N

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Napoleon GDI-30N and is the answer not in the manual?

Napoleon GDI-30N Specifications

General IconGeneral
BrandNapoleon
ModelGDI-30N
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals