EasyManua.ls Logo

Napoleon IR3GN - User Manual

Napoleon IR3GN
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
W415-1355 / 10.01.14
EN
FR
PG
41
$10.00
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
1.36D
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
!
WARNING
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbour’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
If the information in these instructions
are not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with the appliance and
shall be installed.
CERTIFIED
Decorative Product: Not for use as a heating appliance.
BARRIER
SAFETY BARRIER
CONFORMS TO AMERICAN NATIONAL STANDARDS: ANSI Z21.50, CERTIFIED TO CANADIAN CSA 2.22 FOR VENTED GAS FIREPLACES.
IR3GN
NATURAL GAS
IR3GP
PROPANE

Table of Contents

Other manuals for Napoleon IR3GN

Questions and Answers

  • L
    Logan BergerSep 8, 2025
    How to fix a short or loose connection in the sensor rod of my Napoleon IR3GN Indoor Fireplace?
    • K
      Kimberly BassSep 8, 2025
      To address a short or loose connection in the sensor rod, verify all connections are secure. Ensure the connections from the pilot assembly are tight and not grounding out to any metal.
  • R
    Raymond CuevasAug 22, 2025
    What to do if I smell exhaust fumes and have headaches from my Napoleon IR3GN?
    • M
      Maria RossAug 22, 2025
      If you smell exhaust fumes and experience headaches, immediately check the door seal and inspect for any exhaust damage. Ensure the venting is correctly installed. Also, the room may be experiencing negative pressure, so increase the fresh air supply.
  • W
    wallaceericSep 5, 2025
    What should I do if the air shutter on my Napoleon IR3GN is blocked?
    • M
      Michelle MoodySep 5, 2025
      If the air shutter is blocked, make sure that the opening is free of lint or other obstructions.
  • B
    Benjamin WebbSep 3, 2025
    What to do if there is a blockage in the vent of my Napoleon Indoor Fireplace?
    • M
      martineztraceySep 4, 2025
      If there's a blockage in the vent, remove it. In very cold conditions, ice buildup may occur on the terminal and should be removed as needed. To minimize recurrence, it is recommended that vent lengths passing through unheated spaces (attics, garages, crawl spaces) be wrapped with an insulated mylar sleeve, preventing any sagging. Contact your local authorized dealer for more information.
  • B
    Brian ChanSep 2, 2025
    How do I clean a dirty sensor rod on my Napoleon Indoor Fireplace?
    • K
      Kenneth MeadowsSep 2, 2025
      If you suspect a damaged pilot or dirty sensor rod, verify that the ceramic insulator around the sensor rod is not cracked, damaged, or loose. Also, verify the connection from the sensor rod to the sensor wire. Clean the sensor rod with a green Scotch-Brite to remove any contamination. Verify continuity with multimeter with ohms set at the lowest range.
  • A
    Anthony BaileySep 1, 2025
    Why is the transmitter not working on my Napoleon Indoor Fireplace?
    • C
      christophertapiaSep 1, 2025
      If the transmitter isn’t operational, check the battery power and battery orientation.
  • R
    Robert ParrishAug 30, 2025
    How to fix poor flame rectification on Napoleon IR3GN?
    • D
      Derek SchmittAug 30, 2025
      To improve flame rectification, ensure the flame is engulfing the sensor rod. This will increase the flame rectification. Verify correct pilot orifice is installed and inlet gas specifications to manual. The sensor rod may also need cleaning.
  • E
    eugene92Aug 29, 2025
    What to check if my Napoleon IR3GN has no power?
    • J
      John RichardsonAug 29, 2025
      If there's no power to the system, check the breaker to verify it’s in the 'ON' position.
  • G
    Gary GreenAug 27, 2025
    How to unlock the remote for my Napoleon Indoor Fireplace?
    • R
      Robert WestAug 27, 2025
      To reset a locked-out remote, turn the power source off and then on again. Note that if backup batteries are installed, they must also be removed to reprogram.
  • J
    Jose WrightAug 25, 2025
    How to fix flame impinging on glass in Napoleon IR3GN Indoor Fireplace?
    • B
      Brianna BakerAug 25, 2025
      If the flame is hitting the glass, logs, rocks, media, or combustion chamber, ensure the glass, logs, rocks, and media are correctly positioned. Open the air shutter to increase the primary air. Check the input rate by checking the manifold pressure and orifice size as specified by the rating plate. Confirm that the door gasketing is intact and the seal is tight. Verify that both vent liners are free of holes and well-sealed at all joints. Also, confirm that the minimum rise per foot (meters) has been adhered to for any horizontal venting.

Napoleon IR3GN Specifications

General IconGeneral
BrandNapoleon
ModelIR3GN
CategoryIndoor Fireplace
LanguageEnglish