Chapter 4 Programming
©
National Instruments Corporation 4-11 PCI E Series RLPM
8. The function AI_Board_Environmentalize configures the board
for any external multiplexers.
Joint_Reset_Register
AI configuration start = 1;
AI_Mode_2_Register
External mux present = 0;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
9. Call
AI_Trigger_Signals to set the triggering options.
Joint_Reset_Register
AI configuration start = 1;
AI_Mode_1_Register
Trigger once = 1;
AI_Trigger_Select_Register
Start edge = 1;
Start sync = 1;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
10. The function
AI_Scan_Start selects the scan start event.
Joint_Reset_Register
AI configuration start = 1;
AI_Start_Stop_Select_Register
Start edge = 1;
Start sync = 1;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
11. Call the function
AI_End_of_Scan to select the end of scan event.
Joint_Reset_Register
AI configuration start = 1;
AI_Start_Stop_Select_Register
Stop select = 19;
Stop sync = 1;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;

Table of Contents

Other manuals for National Instruments 60 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments 60 Series and is the answer not in the manual?

National Instruments 60 Series Specifications

General IconGeneral
BrandNational Instruments
Model60 Series
CategoryI/O Systems
LanguageEnglish

Related product manuals