EasyManuals Logo

National Instruments 60 Series Programmer's Manual

National Instruments 60 Series
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #89 background imageLoading...
Page #89 background image
Chapter 4 Programming
PCI E Series RLPM 4-26
©
National Instruments Corporation
5. The function AI_Scan_Start selects the scan start event.
Joint_Reset_Register
AI configuration start = 1;
AI_START_STOP_Select_Register = 0x0021;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
6. Perform Analog Input Example 1 Step 11.
7.
Convert_Signal selects the convert signal for the acquisition.
Joint_Reset_Register
AI configuration start = 1;
AI_Mode_2_Register
AI SC gate enable = 1;
AI START STOP gate enable = 1;
AI_Mode_1_Register
AI CONVERT source select = 1;
AI CONVERT source polarity = 1;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
8. Perform Analog Input Example 1 Step 4.
9. Call
AI_Arming to arm the analog input counter.
AI_Command_1_Register
AI SC arm = 1;
AI SI arm = 0;
AI SI2 arm = 0;
AI DIV arm = 1;
10. The function
AI_Start_The_Acquisition starts the acquisition
process.
AI_Command_2_Register
AI START1 pulse = 1;
11. Poll the AI FIFO not empty flag in the AI_Status_1_Register until not
empty and read the ADC FIFO data in the ADC_FIFO_Data_Register.
Do
{
If (AI FIFO not empty) then
read FIFO data;
} while (20 samples have not been read)

Table of Contents

Other manuals for National Instruments 60 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments 60 Series and is the answer not in the manual?

National Instruments 60 Series Specifications

General IconGeneral
BrandNational Instruments
Model60 Series
CategoryI/O Systems
LanguageEnglish

Related product manuals