EasyManuals Logo

National Instruments 60 Series Programmer's Manual

National Instruments 60 Series
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
Chapter 4 Programming
PCI E Series RLPM 4-28
©
National Instruments Corporation
AI_SI_Load_A_Registers (24 bits)
AI SI special ticks -1 = 1
AI_Command_1_Register
AI SI load = 1;
AI_SI_Load_A_Registers (24 bits)
AI AI ordinary ticks -1 = 199;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
8. Perform Analog Input Example 1 Step 11.
9.
Convert_Signal selects the convert signal for the acquisition.
Joint_Reset_Register
AI configuration start = 1;
AI_SI2_Load_A_Register
AI SI2 special ticks -1 = 1;
AI_SI2_Load_B_Register
AI SI2 ordinary ticks -1 = 1;
AI_Mode_2_Register
AI SI2 reload mode = 1;
AI_Command_1_Register
AI SI2 load = 1;
AI_Mode_2_Register
AI SI2 initial load source = 1;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
10. Perform Analog Input Example 1 Step 4.
11. Call
AI_Arming to arm the analog input counter.
AI_Command_1_Register
AI SC arm = 1;
AI SI arm = 1;
AI SI2 arm = 1;
AI DIV arm = 1;
12. Now start the acquisition with
AI_Start_The_Acquisition
.
AI_Command_2_Register
AI START1 pulse = 1;

Table of Contents

Other manuals for National Instruments 60 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments 60 Series and is the answer not in the manual?

National Instruments 60 Series Specifications

General IconGeneral
BrandNational Instruments
Model60 Series
CategoryI/O Systems
LanguageEnglish

Related product manuals