EasyManua.ls Logo

National Instruments cRIO-9068 - Configuring Startup Options; Force Safe Mode; Enable Console Out; Disable RT Startup App

National Instruments cRIO-9068
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ambient Temperature......................................................................................................16
Mounting the Device Directly on a Flat Surface............................................................ 17
Mounting the Device on a Panel..................................................................................... 18
Mounting the Device on a DIN Rail............................................................................... 19
Mounting the Device on a Rack......................................................................................21
Mounting the Device on a Desktop.................................................................................21
Worldwide Support and Services............................................................................................ 23
Configuring Startup Options
Complete the following steps to configure the cRIO-9068 startup options in MAX.
1. In MAX, expand your system under Remote Systems.
2. Select the Startup Settings tab to configure the startup settings.
cRIO-9068 Startup Options
You can configure the following cRIO-9068 startup options.
Table 1. cRIO-9068 Startup Options
Startup Option Description
Force Safe Mode Rebooting the cRIO-9068 with this setting on starts the cRIO-9068
without launching LabVIEW Real-Time or any startup applications. In
safe mode, the cRIO-9068 launches only the services necessary for
updating configuration and installing software.
Enable Console
Out
Rebooting the cRIO-9068 with this setting on redirects the console output
to the RS-232 serial port. You can use a serial-port terminal program to
read the IP address and firmware version of the cRIO-9068. Use a null-
modem cable to connect the RS-232 serial port to a computer. Make sure
that the serial-port terminal program is configured to the following
settings:
115,200 bits per second
Eight data bits
No parity
One stop bit
No flow control
Disable RT
Startup App
Rebooting the cRIO-9068 with this setting on prevents any LabVIEW
startup applications from running.
2 | ni.com | NI cRIO-9068 User Manual