NV5/NV3.5 Troubleshooting Manual Responding to alarms
Issue 3.2 2014-12-10 Page 1-37
NV Controller - 1201370715.41 (2008-01-26T18:05:15)
Main Menu
=========
1 Analog Outputs
2 Factory Defaults
3 Channel Interrogation
4 RTC Calibration
5 Presets
Enter your choice:
5. Select option 3 - Channel Interrogation. The following menu will display:
Channel Interrogation
=====================
1 xxx GET channel xxx
2 xx hh SET channel xx with value hh
3 Back to Main Menu
6. Select option 2 to perform a SET command on the field bias channel (0x0028). The set value
consists of a string of bytes that includes the PA address and the bias information (provided
on the tag of the replacement PA PWB). For example, to program PA #4 (address 0x03) of
module 7 (address 0x16H) with the values 0x70, 0x75, 0x80, 0x85, 0x90 for targets 1 through
5 respectively, enter the following (use single spaces between fields):
2 16010028 3 0 70 0 75 0 80 0 85 0 90<enter>
The controller will respond with the following message:
Setting up channel 16010028 with 03 00 70 00 75 00 80 00 85 00 90...
NV Controller - 1200874030.20 ( 2008-01-21T00:07:10 )
Set successful for channel 0x0028 on board 0x16
NV Controller - 1200874030.28 ( 2008-01-21T00:07:10 )
Channel Interrogation
=====================
1 xxx GET channel xxx
2 xx hh SET channel xx with value hh
3 Back to Main Menu
Enter your choice: