Setup 31
Keys: F5
Enter Key: [CR, CR-LF, TAB]
Select the code the enter key in the numeric keypad transmits.
Return Key: [CR, CR-LF, TAB]
Select the code the return key on the main alphanumeric keypad transmits.
Alt Key (left): [Meta, Legend, Funct, Scroll-Lock, Alt Key]
Select the way in which the left ALT key behaves. In ANSI emulations, Co
mpose is available as a selection instead
of Legend. The Alt Key selection refers to the right Alt key.
Meta sets the most significant bit for the next character and allows 8-bit data to be generated from the
keyboard.
Legend precedes a key from the keyboard and causes the character that is printed on the right-side of
the key to be sent to the terminal or host.
Compose precedes sequences of keys to create a character that is not on the keyboard but is
available in the active character set.
Scroll Lock causes the Alt key to function as the Scroll Lock key, and is a toggle to hold/free data on the
screen. It requires the use of flow control for the host port “Rcv Prtcl”.
Funct causes the Alt key to function as the Funct key on an ASCII keyboard.
Alt Key causes the left Alt key to behave identically to the right Alt key.
Pound Key: [U.S., British]
Choose the character transmitted for 23h: the US pound (#) or the British pound (£).
Return Key Repeat: [On,
Off]
Select whether the Return key located on the alphanumeric keypad will repeat when held down for more than
half a second
(only selectable when “Key Repeat” = On).
Local Leadin: [On, Off]
This parameter is only available when Key Mode (in the Kybd menu) is Sca
nCode. If Local Leadin is off, the only
local function (Appendix A) that is available is Ctrl-Scroll Lock to enter Setup. If Local Leadin is on, the
Setup
keystroke “introduces” the keystroke as local and then local functions can be generated using the keystrokes
listed on page A-1. For example, to enter Setup when ScanCode and Local Leadin are on, press Ctrl-Scroll Lock to
introduce thi
s as a local function , and then Ctrl-Scroll Lock to enter Setup.
Local Leadin will not work if Comm Mode is set to Half Block or Full Block.
PC Keyboard
Disconnect: [Dis
abled, Pause, Alt-Pause]
Select the keystroke that will generate a modem disconnect.
Backspace: [BS/DEL, D
E
L/BS, DEL/CAN, BS/BS]
Choose the codes sent by the backspace key in the normal/shifted positions.
Desk Acc: [Sh-Ctrl-Fkeys, Ctrl , Disabled]
Select how the Desk Accessories can be accessed. This selection does not appear when SCO Console emulation
is sel
ected. In SCO Console emulation, Ctrl is the only access method.
The default allows the desk accessories to be accessed through a menu which appears when Ctrl and the left
arrow key are pressed simultaneously. This brings up a pop-up window; selections for the specific accessory can
be mad
e from that menu by pressing F1-F5. The Sh-Ctrl-Fkeys option, when selected, allows direct access to desk
accessories by pressing Sh-Ctrl-F1 through Sh-Ctrl-F5. Selecting Disabled will inhibit entry to d
esk accessories.
Once a desk accessory is displayed, any other desk accessory can be accessed by pressing only the function key
associated with it (without pressing Sh-Ctrl).
When using PC-Term emulation, Local Leadin (in the F5 menu) must be on to access desk accessories. Then, to
view th
e diagnostic menu, for example, press Ctrl-Scroll Lock, Ctrl-, F5.