EN
Select the charging program suitable for the type of house battery used based on the battery manufacturer's specifi-
cations, the information on the charging curves (see Battery charging function ) and the technical data (see Technical
data ). The specified charging times apply to an average ambient temperature of 20 °C.
Slide the DIP switches to the position shown in the table below to set the charging program for the respective
type of house battery.
Table 2: Charging curve configuration
FunctionDIP switch po-
sition (gray)
Charging program Maximum
voltage
(V
max
)
Maintenance volt-
age (V
maint
)
Desulfation volt-
age (V
des
)
Lead gel batteries
Desulfation off
14.3 V 13.6 V –
Lead gel batteries
Desulfation on
14.3 V 13.6 V 15.8 V
AGM batteries
Desulfation off
14.8 V 13.6 V –
AGM batteries
Desulfation on
14.8 V 13.8 V 15.8 V
Wet batteries
Desulfation off
14.4 V 13.5 V –
Wet batteries
Desulfation on
14.4 V 13.5 V 15.8 V
12