APX
A
Electrical
Power
Section
Battery
Case
-
4
alkali-manganese
cells
(3
AM-3
standard)
Non-rechargeable
Batteries
can
be
exchanged
External
dimensions:
70
mm
width
80.5
mm
depth
19
mm
thickness
Length
of
operation:
AM-3
Up
to
18
hours
{during
con¬
stant
use
at
normal
tempera¬
tures)
SUM-3
Up
to
6
hours
(during
constant
use
at
normal
temperatures)
-
Range:
DC
6
V
600
mA
Batteries
for
Emergency
Operation
50
mA/h
3.6
V
Ni-Cd
batteries
installed
with¬
in
the
PC
8201
Trickle-chargeable
from
whatever
batteries
are
used
as
the
electrical
power
source
for
the
basic
unit
A
battery
discharge
prevention
switch
is
in¬
cluded
Emergency
operation
battery
backup
time
limit:
Up
to
7
days
(with
64K
RAM
at
normal
temperatures)
Up
to
26
days
(with
16K
RAM
at
normal
temperatures)
Power
Off
-
Manual
power-off
by
means
of
the
electrical
power
switch
Controllable
by
means
of
a
POWER
command
in
BASIC
Automatic
power
shutoff
when
no
key
has
been
input
after
10
minutes
(this
possible
input
period
can
be
varied
between
1
minute
and
25
minutes)