1
Back-Up
Power
As
outlined
in
the
section
on
batteries,
the
back
up
power
source
consists
of
internal
nickel-cadmium
batteries.
The
Back
Up
Power
switch
is
on
the
bottom
of
the
PC-8201.
This
switch
must
be
in
the
ON
position
for
the
computer
to
be
operated.
If
the
PC-8201
is
stored
unused
for
more
than
30
days
this
switch
should
be
set
to
OFF
to
prevent
the
total
discharge
of
the
batteries
and
deterioration
in
performance.
When
the
Back
Up
Power
switch
is
turned
OFF
the
RAM
is
completely
erased,
so
it
would
be
wise
to
copy
important
files
or
data
onto
cassette
tape
prior
to
turning
OFF
the
back
up
power.
Automatic
Shut
Off
When
the
PC-8201
is
ON
and
no
key
has
been
pressed
for
over
10
minutes,
the
unit's
power
will
automatically
be
shut
off
to
prevent
excess
discharge
of
the
batteries.
When
the
automatic
shut
off
function
has
been
activated
the
Power
ON/OFF
switch
would
have
to
be
manually
set
to
the
OFF
position
before
turning
the
PC-8201
back
ON.
The
predetermined
time
period
of
10
minutes
for
the
automatic
shut
off
can
be
altered
using
a
BASIC
language
POWER
command.
The
automatic
shut
off
feature
may
be
cancelled
by
the
use
of
the
POWER
CONT
statement
when
the
AC
power
adapter
is
connected
to
the
PC-8201.
See
the
BASIC
Reference
Manual
for
explana¬
tions
of
these
commands.
The
only
time
that
the
automatic
shut
off
cannot
be
activated
is
when
the
PC-8201
is
in
the
TERM
mode
of
the
TELCOM
feature
or
when
a
BASIC
program
is
being
run.
See