Issue 2.00 UNIVERGE SV8100
3 - 8 Equipment
SLT Adapter Standard (-28V) : 0.8
Long Line (-48V) : 2
. ITL factors are calculated using the CD-ETIA blade.
. Power requirements for the 9.5 “ chassis are the same as the
19” chassis.
Table 3-6 Terminal Power Factor (Continued)
Terminal Power Factor
19 inch Metal Chassis with Fan =<80
9.5 inch Plastic Chassis without Fan =<64
Item Power Factor
Table 3-7 IP Terminal Power Chart
IP
Terminal
IEEE802.
3af
Class
Label Indication
(Maximum Current with All Options)
Maximum Current Without Options
48VDC 24VDC 48VDC 24VDC
ITL-320C-1 TEL Class 3 160mA 7.7W 290mA 7.0W 111mA 5.3W 192mA 4.6W
ITL-32D-1 TEL Class 2 130mA 6.2W 235mA 5.6W 90mA 4.3W 153mA 3.7W
ITL-8LD-1 TEL Class 2 130mA 6.2W 235mA 5.6W 81mA 3.9W 137mA 3.3W
ITL-24D-1 TEL Class 2 130mA 6.2W 235mA 5.6W 81mA 3.9W 137mA 3.3W
ITL-12D-1 TEL Class 2 130mA 6.2W 235mA 5.6W 81mA 3.9W 137mA 3.3W
ITL-24PA-1 TEL Class 2 130mA 6.2W 235mA 5.6W
–
0.0W
–
0.0W
ITL-24PD-1 TEL Class 2 130mA 6.2W 235mA 5.6W
–
0.0W
–
0.0W
ITL-24BT-1 TEL Class 2 130mA 6.2W 235mA 5.6W
–
0.0W
–
0.0W
ITL-6DE-1 TEL Class 1 68mA 3.3W 122mA 2.9W 68mA 3.3W 122mA 2.9W
ITL-2E-1 TEL Class 1 68mA 3.3W 122mA 2.9W 68mA 3.3W 122mA 2.9W
Label Indication:
IP Value/Sophisticated – Maximum watts when adding options or modular upgrades.
IP Value – Maximum watts when ITL-12D-1 TEL is changed to ITL-8LD-1 TEL or ITL-24D-1 TEL.