UNIVERGE SV8100 Issue 2.00
Configuration Guide 5 - 11
SECTION 4 POWER REQUIREMENTS
A dedicated 100VAC/120VAC/220VAC/230 – 240VAC 50Hz/60Hz circuit located within
seven feet of the chassis is required. A separate dedicated outlet for each chassis
should be installed.
4.1 Power Supply Specifications
AC Power Supply:
Dedicated 15 Amp circuit
Power Requirements: 230 VAC @ 15A Controlling/Base Chassis
Power Consumption: Base Chassis=263VA,
Expansion Chassis=263VA, total 1052VA
Input Voltage: 90VAC to 264VAC
(Rated Voltage: 100VAC/120VAC/220VAC - 240VAC)
Frequency: 47Hz – 63Hz (Rated frequency: 50/60Hz)
Phase and Wire: Single Phase, 2 Line + PE Type
Grounding Requirements: No. 14 AWG copper wire
Feeding Voltage: D
term
/OPX/DID: -48V
SLT: 25mA / -28V
With input voltage of 230 VAC and with full load conditions:
Output Power: Base chassis=130W, Expansion chassis=130W, total 520W
AC Input I: Base chassis=1.15A, Expansion chassis=1.15A, total 4.6A
VA @ 230V: Base chassis=276VA, Expansion chassis=276VA,
total 1104VA
Table 5-8 Cabling Requirements
Connected Equipment Cable
Music on Hold and Background Music Sources Hi-Fi Shielded Audio Cable
External Amplifier Hi-Fi Shielded Audio Cable
ITL Cabling
Cat 5 Straight Data Network
Cable – 328.1 ft (100m)
maximum distance.
Double Pole/Neutral Fusing (power supply fuses are located at
both the L and N side).

Table of Contents