Figure 5-3 Connecting the DLC Using Twisted 2-Pair Cable is a diagram of the
chassis connected with each of the multiline terminals and single line telephones by a
separate twisted 1-pair cable or 2-pair cable (only for multiline terminals).
Refer to the following tables for cabling requirements and specifications:
Table 5-4 DT300 Series Loop Resistance and Cable Length
Table 5-5 DT700 Series Loop Resistance and Cable Length
Table 5-6 Dterm Series i or Dterm IP Terminal Loop Resistance and Cable
Length
Table 5-7 Cable Connection Between the Analog Port and the Single Line
Equipment
Table 5-8 Cabling Requirements
Figure 5-3 Connecting the DLC Using Twisted 2-Pair Cable
Table 5-4 DT300 Series Loop Resistance and Cable Length
Terminal or Adapter
By Twisted 1-Pair
Cable (without
AC Adapter)
24 AWG
By Twisted 1-Pair
Cable (with AC
Adapter)
24 AWG
DTL-2E-1 (BK) TEL
1,969 ft (600m) 6,562 ft (2000m)
DTL-6DE-1 (BK) TEL
1,969 ft (600m) 6,562 ft (2000m)
DTL-8LD-1 (BK) TEL
DTL-8LD-1 (WH) TEL
1,969 ft (600m) 6,562 ft (2000m)
DTL-12BT-1 (BK) TEL
1,969 ft (600m) 6,562 ft (2000m)
DTL-12PA-1 (BK) TEL
1,969 ft (600m) 6,562 ft (2000m)
DTL-12D-1 (BK) TEL
DTL-12D-1 (WH) TEL
1,969 ft (600m) 6,562 ft (2000m)
DTL-24D-1(BK) TEL
DTL-24D-1(WH) TEL