5 - 12 Hardware Specifications
KWh @ AC Input I x 230V/1000: Base chassis=0.276 KWh,
Expansion chassis=0.276 KWh, total 1.104 KWh
BTU (KWh x 3413): Base chassis=898 BTU,
Expansion chassis=898 BTU, total 3592 BTU
A dedicated outlet, separately fused and grounded for each chassis should
be installed
4.2 Power Supply Consumption
SECTION 5 ENVIRONMENTAL CONDITIONS
5.1 Temperature and Humidity
Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F (-20°C ~ 60°C)
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades/Daughter Boards – PZ-BS10, PZ-BS11, PZ-VM21, PZ-ME50,
CD-8DLCA, CD-16DLCA, PZ-8DLCB
Operating Temperature: +32°F ~ +104
o
F (0
o
C ~ 40
o
C)
Recommended Long Term Temperature: -4°F ~ +140°F (-20°C ~ 60°C)
Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades/Daughter Boards – CD-4LCA, PZ-4LCA, CD-8LCA, PZ-8LCE,
CD-4COTA, PZ-4COTE, CD-PRTA
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F (-20°C ~ 60°C)
Table 5-9 Power Consumption
Chassis
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic Chassis – CD-CP00 Chassis
2.19A 96 130
Basic Chassis + Expansion Chassis
4.38A 192 260
Basic Chassis + 2 Expansion Chassis
6.57A 288 390
Basic Chassis + 3 Expansion Chassis
8.76A 384 520