UNIVERGE SV8100 Issue 2.00
Configuration Guide 5 - 9
DTL-32D-1 (BK) TEL
DTL-32D-1 (WH) TEL
1,969 ft (600m) 6,562 ft (2000m)
DCL-60-1 Console*
1,969 ft (600m) -
* An AC Adapter is required.
Table 5-5 DT700 Series Loop Resistance and Cable Length
Terminal or Adapter Ethernet Cable
ITL-2E-1 (BK) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-6DE-1 (BK) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-8LD-1 (BK) TEL
ITL-8LD-1 (WH) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-12D-1 (BK) TEL
ITL-12D-1 (WH) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-12PA-1 (BK) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-24D-1 (BK) TEL
ITL-24D-1 (WH) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100 m)
ITL-32D-1 (BK) TEL
ITL-32D-1 (WH) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-32OC-1 (BK) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
Table 5-4 DT300 Series Loop Resistance and Cable Length (Continued)
Terminal or Adapter
By Twisted 1-Pair
Cable (without
AC Adapter)
24 AWG
By Twisted 1-Pair
Cable (with AC
Adapter)
24 AWG