Issue 7.00
InMail System Guide 2 - 339
Programming
1. Set up a Subscriber Mailbox.
47-02-01 Mailbox Active (Mailbox Active)
Activate (1) the Subscriber Mailbox.
. By default, Subscriber Mailboxes 1~8 are active (1). All other Subscriber
Mailboxes are inactive (0).
47-02-02 Mailbox Number (Mailbox Number)
Assign the mailbox number to each active Subscriber mailbox. Normally,
the mailbox number is the same as the extension number.
. By default, mailboxes 1~8 correspond to mailbox numbers 200~207.
. Be aware that mailboxes beginning with a leading digit of either 0, * and # are not
supported.
2. Check to be sure message waiting lamp is enabled for the Subscriber Mailbox.
47-02-08 Message Waiting Lamp (Update MW Lamp)
Enter 1 (Yes) to enable Message Waiting lamp for each Subscriber Mailbox.
. By default, this option is 1 (Yes).
3. Set the maximum length of recorded messages left in the Subscriber Mailbox.
47-01-03 Subscriber Message Length (Subs Msg Length)
Set the maximum length (1~4095 seconds) of recorded messages for:
Subscriber Mailbox users dialing RS to record and send a message.
Extension users leaving a message in a Subscriber Mailbox.
Outside Automated Attendant callers accessing a mailbox via a GOTO
command and then dialing RS to record and send a message.
Subscriber Mailbox Greetings.
Announcement Messages.
Call Routing Mailbox Instruction Menus.
. By default, these messages are 120 seconds long maximum.
4. Set the maximum length of recorded Quick Messages left in the Subscriber
Mailbox.
47-01-04 Non-Subscriber Message Length (Mbox Msg Length)
Set the maximum length (1~4095 seconds) of recorded messages for:
Automated Attendant callers leaving a message or Quick Message in a
Subscriber Mailbox.
Outside callers transferred by an extension user to a Subscriber Mailbox.
. By default, these messages are 120 seconds long maximum.