Issue 7.00
3 - 442 Programming
Type 1 (Day of Week) Example
In this example, Answer Table 1 routes calls as follows:
Schedule 1 uses Routing Mailbox 2 and runs Sunday from 8:30AM to
5:00PM.
Schedule 2 uses Subscriber Mailbox 3 and runs Wednesday from 10:30AM
to 5:00PM.
Schedule 3 uses Routing Mailbox 4 and runs Tuesday from 9:00AM to
10:00AM.
At all other times, routing is handled by the Default Mailbox specified in 47-
11-03 Default Mailbox Category and 47-11-03 Default Mailbox Number.
When setting up Answer Tables with multiple types, build the Answer
Schedules in the following order:
Range of Days
Day of Week
Date
KL
Scroll consecutively backwards or forwards through selected Option or Series.
47-12 InMail Answer Schedules (Continued)
(Entry Range) [Default Setting]
Type 1 (Day of Week) Example
Answer Table 1
Answer Schedule 1
Answer Schedule 1 is a Day of Week schedule that runs Sunday from 8:30AM to
5:00PM.
47-12-01 Entry01 Schedule Type = 1
47-12-02 Entry01 MB Ctg = 3
47-12-03 Entry01 MB Num = 2
47-12-04 Entry01 Day = 1
47-12-05 Entry01 Start Day = 1 (Entry does not matter)
47-12-06 Entry01 End Day = 1 (Entry does not matter)
47-12-07 Entry01 Date (MMDD) = 0000 (Entry does not matter)
47-12-08 Entry01 Start Time = 0830 (8:30AM)
47-12-09 Entry01 End Time = 1700 (5:00PM)
Answer Schedule 2
Answer Schedule 2 is a Day of Week schedule that runs Wednesday
from10:30AM to 5:00PM.
47-12-01 Entry01 Schedule Type = 1
47-12-02 Entry01 MB Ctg = 1
47-12-03 Entry01 MB Num = 3