Issue 7.00
InMail System Guide 3 - 445
Type 3 (Date) Example
In this example, Answer Table 1 routes calls as follows:
Schedule 1 uses Routing Mailbox 1 and runs every day from 8:30AM to
5:00PM.
Schedule 2 uses Routing Mailbox 9 and runs only on Christmas Day from
8:30AM to 5:00PM.
At all other times, routing is handled by the Default Mailbox specified in
47-11-04 Default Mailbox Category and 47-11-05 Default Mailbox Number.
When setting up Answer Tables with multiple types, build the Answer Schedules
in the following order:
Range of Days
Day of Week
Date
Type 3 (Date) Example
Answer Table 1
Answer Schedule 1
Answer Schedule 1 is a Range of Days schedule that starts schedule that runs
every day from 8:30AM to 5:00PM.
47-12-01 Entry01 Schedule Type = 2
47-12-02 Entry01 MB Ctg = 3
47-12-03 Entry01 MB Num = 1
47-12-04 Entry01 Day = 1 (Entry does not matter)
47-12-05 Entry01 Start Day = 1 (Sunday)
47-12-06 Entry01 End Day = 1 (Sunday)
47-12-07 Entry01 Date (MMDD) = 0000 (Entry does not matter)
47-12-08 Entry01 Start Time = 0830 (8:30AM)
47-12-09 Entry01 End Time = 1700 (5:00PM)
Answer Schedule 2
Answer Schedule 2 is a Date schedule that runs only on Christmas Day from
8:30AM to 5:00PM.
47-12-01 Entry01 Schedule Type = 3
47-12-02 Entry01 MB Ctg = 3
47-12-03 Entry01 MB Num = 9
47-12-04 Entry01 Day = 1 (Entry does not matter)
47-12-05 Entry01 Start Day = 1 (Entry does not matter)
47-12-06 Entry01 End Day = 1 (Entry does not matter)
47-12-07 Entry01 Date (MMDD) = 1225 (December 25, Christmas
Day)
47-12-08 Entry01 Start Time = 0830 (8:30AM)
47-12-09 Entry01 End Time = 1700 (5:00PM)