EasyManua.ls Logo

NEC Xen Topaz - Page 225

NEC Xen Topaz
390 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XEN Topaz NEC Business Solutions Ltd
Features and Specifications Manual Chapter 4 - 217
Doc. No. 8846 - Release 2.0
April 2005
Direct Inward Dialling (DID) / Direct Inward Line (DIL) / Direct Inward
System Access (DISA)
Transferred DID, DIL, and DISA calls do not require ring group programming.
•Operation
To place a call on a loop key:
1. Press outgoing or both ways loop key.
You hear dial tone and the key lights green.
2. Dial number.
To answer a call on a loop key:
Listen for ringing a look for a flashing loop key.
1. Press loop key.
The key lights green and you connect to the call.
If there are additional calls waiting to be answered, your display shows:
WAITING - LOOP KEY
To program a loop key:
1. Press the SPK key.
2. Dial 852.
3. Press the key you want to program as a loop key.
4. Dial *05.
5. Dial the loop key type:
0 = Incoming only
1 = Outgoing only
2 = Both ways (incoming and outgoing)
6. Dial the loop key routing option for incoming, outgoing, or incoming and outgoing calls:
000 = Trunk Group Routing or ARS (if installed)
01-25 = Trunk Groups
If you selected option 2 in step 5 above, enter the incoming Trunk Group followed by the outgoing Trunk
Group.
7. Press SPK to hang up.